Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28.442
Filtrar
1.
J Cardiothorac Surg ; 19(1): 170, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38566230

RESUMO

BACKGROUND: Open repair of thoracoabdominal aortic aneurysm (TAAA) was characterized by significant risk of postoperative mortality and morbidity. The aim of this study was to determine the perioperative predictors of early and long-term mortality in patients undergoing open repair of TAAA. Besides, the postoperative outcomes in patients with open repair of TAAA were described. METHODS: This is a single-center retrospective study, and 146 patients with open repair of TAAA from January 4, 2011, to November 22, 2018 was involved. Categorical variables were analyzed by the Chi-square test or Fisher's exact test, and continuous variables were analyzed by the independent sample t-test and the WilCoxon rank-sum test. Multivariate Logistic regression and Cox regression were applied to identify the predictors of 30-day and long-term mortality, respectively. The Kaplan Meier curves were used to illustrate survival with the Log-rank test. RESULTS: The 30-day mortality was 9.59% (n = 14). Older than 50 years, the intraoperative volume of red blood cell (RBC) and epinephrine use were independently associated with postoperative 30-day mortality in open repair of TAAA. Long-term mortality was 17.12% (n = 25) (median of 3.5 years (IQR = 2-5 years) of follow-up). Prior open thoracoabdominal aortic aneurysm (TAAA) repair, aortic cross-clamping (ACC) time, intraoperative volume of RBC and use of epinephrine were independently correlated with long-term mortality. CONCLUSIONS: Identifying perioperative risk factors of early and long-term mortaliy is crucial for surgeons. Intraoperative volume of RBC and use of epinephrine were predictors of both early and long-term mortality. In addition, patients of advanced age, prior open repair of TAAA and prolonged ACC time should be paid more attention.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Torácica/complicações , Resultado do Tratamento , Estudos Retrospectivos , Implante de Prótese Vascular/efeitos adversos , Fatores de Risco , Epinefrina , Complicações Pós-Operatórias/etiologia , Procedimentos Endovasculares/efeitos adversos , Medição de Risco
2.
Sci Rep ; 14(1): 8057, 2024 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-38580650

RESUMO

The potential of adverse events (AEs) after thoracic endovascular aortic repair (TEVAR) in patients with type B aortic dissection (TBAD) has been reported. To avoid the occurrence of AEs, it is important to recognize high-risk population for prevention in advance. The data of 261 patients with TBAD who received TEVAR between June 2017 and June 2021 at our medical center were retrospectively reviewed. After the implementation of exclusion criteria, 172 patients were finally included, and after 2.8 years (range from 1 day to 5.8 years) of follow up, they were divided into AEs (n = 41) and non-AEs (n = 131) groups. We identified the predictors of AEs, and a prediction model was constructed to calculate the specific risk of postoperative AEs at 1, 2, and 3 years, and to stratify patients into high-risk (n = 78) and low-risk (n = 94) group. The prediction model included seven predictors: Age > 75 years, Lower extremity malperfusion (LEM), NT-proBNP > 330 pg/ml, None distal tear, the ratio between the diameter of the ascending aorta and descending aorta (A/D ratio) > 1.2, the ratio of the area of the false lumen to the total aorta (FL ratio) > 64%, and acute TEVAR, which exhibited excellent predictive accuracy performance and discriminatory ability with C statistic of 82.3% (95% CI 77.3-89.2%). The prediction model was contributed to identify high-risk patients of postoperative AEs, which may serve to achievement of personalized treatment and follow-up plans for patients.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Idoso , Correção Endovascular de Aneurisma , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Estudos Retrospectivos , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Fatores de Tempo , Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Fatores de Risco
3.
Ann Card Anaesth ; 27(2): 162-164, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38607881

RESUMO

ABSTRACT: We report a case of simultaneous transcatheter aortic valve replacement and endovascular aneurysm repair. Our aim was to advocate the role of local and regional anesthesia as a key contributor in maintaining hemodynamic stability and avoiding abrupt blood pressure change. Endovascular combined procedures are gaining popularity for their numerous advantages. Nevertheless, they carry significant risks for their hemodynamic implications. It is imperative to acknowledge the modifications occurring after each correction and act accordingly. Different anesthesia approaches can dramatically influence hemodynamics; among all, we found local and regional anesthesia would better serve this objective.


Assuntos
Anestesia por Condução , Anestésicos , Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Substituição da Valva Aórtica Transcateter , Humanos , Aneurisma da Aorta Abdominal/cirurgia
4.
Medicine (Baltimore) ; 103(14): e37731, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38579061

RESUMO

RATIONALE: A hostile iliac access route is an important consideration when enforcing endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA). Herein, we report a case of AAA with unilateral external iliac artery occlusion, for which bifurcated EVAR was successfully performed using a single femoral and brachial artery access. PATIENT CONCERNS: A 76-year-old man who had undergone surgery for lung cancer 4.5 years prior was diagnosed AAA by computed tomography (CT). DIAGNOSIS: Two and a half years before presentation, CT revealed an infrarenal 48 mm AAA, which had enlarged to 57 mm by 2 months preoperatively. CT identified occlusion from the right external iliac artery to the right common femoral artery, with no observed ischemic symptoms in his right leg. The right external iliac artery, occluded and atrophied, had a 1 to 2 mm diameter. INTERVENTION: Surgery was commenced with the selection of a Zenith endovascular graft (Cook Medical) with an extended body length. Two Gore Viabahn VBX balloon expandable endoprosthesis (VBX; W.L. Gore & Associate) were delivered from the right axilla as the contralateral leg. OUTCOMES: CT scan on the 2nd day after surgery revealed no endoleaks. LESSONS: While the long-term results remain uncertain, this method may serve as an option for EVAR in patients with unilateral external iliac artery occlusion.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco , Masculino , Humanos , Idoso , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Implante de Prótese Vascular/métodos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgia , Axila/cirurgia , Perna (Membro)/cirurgia , Procedimentos Endovasculares/métodos , Stents , Resultado do Tratamento , Aneurisma Ilíaco/cirurgia
5.
J Cardiothorac Surg ; 19(1): 203, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38615049

RESUMO

BACKGROUND: Open arch surgery is technically demanding for the surgeon and surgically and biologically invasive for the patient, requiring a variably long period of hypothermic circulatory arrest. CASE PRESENTATION: Here we present a case of an elderly patient with chronic renal failure and multiple splanchnic artery disease successfully treated for a rupturing pseudoaneurysm of the aortic arch with a technique that we developed for particularly frail patients. The procedure includes: triple supra-aortic vessel perfusion; distal thoracic aorta antegrade perfusion; balloon endo-clamping of the descending aorta; and anastomosis of an off-the-shelf hybrid arch prosthesis in Ishimaru zone 0. These maneuvers allowed to maintain an extracorporeal circulation in the phase of distal anastomosis, instead of a period of circulatory arrest, employing just mild hypothermia: technical details are depicted and discussed also in comparison with other methods proposed in the literature. CONCLUSIONS: Being able to take advantage of both open surgery advancements and endovascular methods is the key to cardiovascular surgery success today in front of complex pathologies of the aorta: increasing safety and reducing invasiveness of therapeutic options may progressively extend surgical candidacy to the frailest patients.


Assuntos
Implante de Prótese Vascular , Parada Cardíaca , Idoso , Humanos , Aorta Torácica/cirurgia , Aorta , Perfusão
6.
J Cardiothorac Surg ; 19(1): 199, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600502

RESUMO

BACKGROUND: Total endovascular technique with fenestrated endovascular graft might be hampered for the late dilatation of proximal landing zone, which may cause endografts migration. We describe a successful urgent hybrid procedure for extent III thoracoabdominal aortic aneurysm with aortic intramural hematoma. CASE PRESENTATION: A 55-year-old female with thoracoabdominal aortic aneurysm was considered at high surgical risk and unfit for open repair due to multiple comorbidities. Therefore, a hybrid procedure of surgeon-modified fenestrated endovascular graft combined with thoracoscope-assisted Transaortic epicardial fixation of endograft was finally chosen and performed in the endovascular operating room. A 3-port technique was performed through a left video-assisted thoracoscopic approach. After the first tampering stent-graft was deployed, a double-needle suture was penetrated both the aortic wall and stent-graft to fixate it in the proximal descending aorta. Then the second endograft, which had been fenestrated on table, was introduced and oriented extracorporeally by rotating superior mesenteric artery and left renal artery fenestration radiopaque markers and deployed with perfect apposition between the fenestrations and target visceral artery. Each vessel was sequentially stented using Viabahn self-expandable stent to finish target vessel stenting. An Ankura cuff stent was deployed in the distal abdominal aortic artery. CONCLUSION: Surgeon-modified fenestrated endovascular graft combined with thoracoscope-assisted fixation may be an innovative and viable alternative for selected high-risk patients with extent III thoracoabdominal aortic aneurysm. A longer follow-up is needed to ascertain the success of this approach.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Cirurgiões , Feminino , Humanos , Pessoa de Meia-Idade , Prótese Vascular , Implante de Prótese Vascular/métodos , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Toracoscópios , Resultado do Tratamento , Stents , Procedimentos Endovasculares/métodos , Desenho de Prótese , Aneurisma da Aorta Abdominal/cirurgia
7.
J Cardiothorac Surg ; 19(1): 237, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627730

RESUMO

Redo ascending and aortic arch surgeries following previous cardiac or aortic surgery are associated with high risk of morbidity and mortality due to multiple factors included sternal re-entry injury, extensive aortic arch surgery, emergency aortic surgery, prolonged cardiopulmonary bypass duration, poor heart function, and patients with older age. Therefore, appropriate surgical strategies are important. We report a case of a 72-year-old gentleman with previous surgery of aortic root replacement who presented with acute Type A aortic dissecting aneurysm of ascending and aortic arch complicated with left hemothorax, which was successfully treated by emergency redo aortic surgery with frozen elephant trunk (FET) technique.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Masculino , Humanos , Idoso , Aorta Torácica/cirurgia , Prótese Vascular , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Valva Aórtica/cirurgia , Dissecção Aórtica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Stents
8.
J Cardiothorac Surg ; 19(1): 226, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627818

RESUMO

BACKGROUND: Sex-related dissimilarities' influence on outcomes following thoracic aortic surgery is poorly understood. Our aim is to examine sex-related disparities in patients undergoing thoracic aortic aneurysm (TAA). METHODS: A total of 455 cases undergoing thoracic aortic aneurysm (TAA) surgery were consecutively enrolled between December 2009 and December 2015 in a Chinese hospital. Primary outcomes, including overall mortality and related risk factors, were evaluated. Cox regression is utilized to recognize the independent risk factor of these consequences. RESULTS: Females, compared to males, had greater indexed aortic diameters and higher aortic transvalvular pressure differences. For the location of aortic aneurysms, females had a higher rate of aortic arch involvement, while males had a higher rate of root involvement. Females underwent less frequent complex proximal aortic operations compared with males (29.5% versus 46.9%; p < 0.001). Women and men both had a lower rate of aortic transvalvular pressure difference and LV volume index 7 days after thoracic aortic surgery. The overall mortality for the women's groups (11%) was suggestively greater compared to 4.9% for the men's groups (p = 0.026). Renal failure and aortic arch involvement were the main risk factors associated with males' survival, while maximum indexed aortic diameter and cross-clamp time were the risk factors associated with females' survival. CONCLUSIONS: The outcome after TAA surgery was less favorable in women with significantly increased overall mortality. It highlights the need to focus on implementing personalized surgery strategies and gender-specific guidelines in treating female patients following TAA surgery.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Cirúrgicos Torácicos , Masculino , Humanos , Feminino , Estudos Retrospectivos , Aneurisma da Aorta Torácica/etiologia , Aorta Torácica/cirurgia , Fatores de Risco , Resultado do Tratamento , Implante de Prótese Vascular/efeitos adversos
9.
Arterioscler Thromb Vasc Biol ; 44(5): 1065-1085, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38572650

RESUMO

Blood vessels are subjected to complex biomechanical loads, primarily from pressure-driven blood flow. Abnormal loading associated with vascular grafts, arising from altered hemodynamics or wall mechanics, can cause acute and progressive vascular failure and end-organ dysfunction. Perturbations to mechanobiological stimuli experienced by vascular cells contribute to remodeling of the vascular wall via activation of mechanosensitive signaling pathways and subsequent changes in gene expression and associated turnover of cells and extracellular matrix. In this review, we outline experimental and computational tools used to quantify metrics of biomechanical loading in vascular grafts and highlight those that show potential in predicting graft failure for diverse disease contexts. We include metrics derived from both fluid and solid mechanics that drive feedback loops between mechanobiological processes and changes in the biomechanical state that govern the natural history of vascular grafts. As illustrative examples, we consider application-specific coronary artery bypass grafts, peripheral vascular grafts, and tissue-engineered vascular grafts for congenital heart surgery as each of these involves unique circulatory environments, loading magnitudes, and graft materials.


Assuntos
Prótese Vascular , Hemodinâmica , Humanos , Animais , Modelos Cardiovasculares , Falha de Prótese , Estresse Mecânico , Fenômenos Biomecânicos , Mecanotransdução Celular , Implante de Prótese Vascular/efeitos adversos , Desenho de Prótese , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/etiologia , Remodelação Vascular
10.
J Cardiothorac Surg ; 19(1): 189, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589942

RESUMO

BACKGROUND: This study aimed to elucidate the methodology and assess the efficacy of the aortic arch inclusion technique using an artificial blood vessel in managing acute type A aortic dissection (ATAAD). METHODS: We conducted a retrospective review of 18 patients (11 males and 7 females, average age: 56.2 ± 8.6 years) diagnosed with ATAAD who underwent total aortic arch replacement (TAAR) using an artificial vascular "inclusion" between June 2020 and October 2022. During the operation, deep hypothermic circulatory arrest (DHCA) and selective antegrade cerebral perfusion (ACP) of the right axillary artery were employed for brain protection. The 'inclusion' total aortic arch replacement and stented elephant trunk (SET) surgery were performed. RESULTS: Four patients underwent the Bentall procedure during the study, with one additional patient requiring coronary artery bypass grafting (CABG) due to significant involvement of the right coronary orifice. Three patients died during postoperative hospitalization. Other notable complications included two cases of postoperative renal failure necessitating continuous renal replacement therapy (CRRT), one case of postoperative double lower limb paraplegia, and one case of cerebral infarction resulting in unilateral impairment of the left upper limb. Eleven patients underwent computed tomography angiography (CTA) examinations of the aorta three months to one-year post-operation. The CTA results revealed thrombosis in the false lumen surrounding the aortic arch stent in seven patients and complete thrombosis of the false lumen around the descending aortic stent in eight patients. One patient had partial thrombosis of the false lumen around the descending aortic stent, and another patient's false lumen in the thoracic and abdominal aorta completely resolved after one year of follow-up. CONCLUSIONS: Incorporating vascular graft in aortic arch replacement simplifies the procedure and yields promising short-term outcomes. It achieves the aim of total arch replacement using a four-branch prosthetic graft. However, extensive sampling and thorough, prolonged follow-up observations are essential to fully evaluate the long-term results.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Substitutos Sanguíneos , Implante de Prótese Vascular , Trombose , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Dissecção Aórtica/cirurgia , Stents , Aorta Abdominal/cirurgia , Paraplegia , Trombose/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Resultado do Tratamento
11.
J Cardiothorac Surg ; 19(1): 239, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632653

RESUMO

OBJECTIVES: Aortic pathologies often present with elevated inflammatory biomarkers due to the nature of the disease. Open aortic surgery causes significant trauma to the body due to often mandatory ischemic periods, long cardiopulmonary bypass times and polytransfusion. We aim to determine postoperative trends on inflammation biomarkers for different aortic pathologies and type of surgery in different segments of the aorta. METHODS: Retrospective review of prospectively collected data of 193 consecutive patients who underwent aortic surgery in our centre between 2017 and 2021, grouped according to the type of aortic intervention: (1) Type A aortic dissection (AD) repair with ascending aorta/hemiarch replacement, (2) Aortic root replacement (ARR), (3) Aortic arch + Frozen elephant trunk (FET), (4) Descending thoracic aorta (DTA)/Thoraco-Abdominal aortic repair (TAA). Primary outcomes were daily values of white blood cells (WBC) and C-Reactive Protein (CRP) during the first 15 postoperative days. RESULTS: All groups had a similar inflammatory peak in the first 2-4 days (WBC 12-15 × 109 c/L). AD and FET groups show similar trends with WBC and CRP peaks on days 2 and 10. The ARR group didn't experience the 2nd peak as most patients were already discharged. DTA/TAA patients experienced a more prolonged inflammatory response, reaching a plateau by day 5-10. AD group shows the highest WBC levels and the DTA/TAAA group the highest CRP levels. CRP levels remain elevated (100-200 mg/L) in all groups after 15 postoperative days. CONCLUSIONS: Inflammatory biomarkers show different postoperative trends depending on the clinical presentation and complexity of the aortic procedure performed. Further understanding of the inflammatory response to different aortic pathologies and surgical procedures will permit reduction on the liberal use of antibiotics that this cohort of patients are usually exposed to. An earlier version of the data included in this manuscript was presented as Oral Abstract in the UK Society of Cardiothoracic Surgery Annual meeting in 2021.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Humanos , Implante de Prótese Vascular/métodos , Aorta/cirurgia , Aorta Torácica/cirurgia , Estudos Retrospectivos , Inflamação , Biomarcadores , Aneurisma da Aorta Torácica/cirurgia , Resultado do Tratamento , Prótese Vascular
12.
Sci Rep ; 14(1): 8924, 2024 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637613

RESUMO

Accurate measurement of abdominal aortic aneurysm is essential for selecting suitable stent-grafts to avoid complications of endovascular aneurysm repair. However, the conventional image-based measurements are inaccurate and time-consuming. We introduce the automated workflow including semantic segmentation with active learning (AL) and measurement using an application programming interface of computer-aided design. 300 patients underwent CT scans, and semantic segmentation for aorta, thrombus, calcification, and vessels was performed in 60-300 cases with AL across five stages using UNETR, SwinUNETR, and nnU-Net consisted of 2D, 3D U-Net, 2D-3D U-Net ensemble, and cascaded 3D U-Net. 7 clinical landmarks were automatically measured for 96 patients. In AL stage 5, 3D U-Net achieved the highest dice similarity coefficient (DSC) with statistically significant differences (p < 0.01) except from the 2D-3D U-Net ensemble and cascade 3D U-Net. SwinUNETR excelled in 95% Hausdorff distance (HD95) with significant differences (p < 0.01) except from UNETR and 3D U-Net. DSC of aorta and calcification were saturated at stage 1 and 4, whereas thrombus and vessels were continuously improved at stage 5. The segmentation time between the manual and AL-corrected segmentation using the best model (3D U-Net) was reduced to 9.51 ± 1.02, 2.09 ± 1.06, 1.07 ± 1.10, and 1.07 ± 0.97 min for the aorta, thrombus, calcification, and vessels, respectively (p < 0.001). All measurement and tortuosity ratio measured - 1.71 ± 6.53 mm and - 0.15 ± 0.25. We developed an automated workflow with semantic segmentation and measurement, demonstrating its efficiency compared to conventional methods.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Calcinose , Procedimentos Endovasculares , Trombose , Humanos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aprendizagem Baseada em Problemas , Semântica , Tomografia Computadorizada por Raios X , Processamento de Imagem Assistida por Computador
13.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38598445

RESUMO

OBJECTIVES: The indications for use, evidence base and experience with the novel noncovered open hybrid surgical stents for acute type A aortic dissection repair for concurrent stabilization of the 'downstream' aorta remains limited. We review the evidence base and the development of these stents. METHODS: Data were collected from Pubmed/Medline literature search to develop and review the evidence base for safety and efficacy of non-covered surgical stents. Existing guidelines for use and developments were reviewed. RESULTS: A single randomized control trial and 4 single-centre studies were included in the review with a total worldwide experience of 241 patients. The deployment was easy and did not add significantly to the primary operation. The mortality and new stroke ranged from 6.3-18.7%. Safe and complete deployment was accomplished in 92-100%. There was no device-related reintervention. There was a significant improvement in malperfusion in over 90% of the cases with varying degrees of remodelling (60-90%) of the downstream aorta. CONCLUSIONS: Open noncovered stent grafts represent a major technical advancement as an adjunct procedure for acute dissection repairs, e.g. hemiarch repair. It has potential for wider use by non-aortic surgeons due to simplicity of technique. Limited safety and efficacy data confirm the device to be safe, feasible and reproducible with potential for wider adoption. However, long-term trial and registry data are required before recommendations for standard use outside of high-volume experienced aortic centres.


Assuntos
Dissecção Aórtica , Implante de Prótese Vascular , Stents , Humanos , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/métodos , Procedimentos Endovasculares/efeitos adversos , Doença Aguda , Desenho de Prótese , Aneurisma da Aorta Torácica/cirurgia , Resultado do Tratamento , Aneurisma Aórtico/cirurgia
14.
Trials ; 25(1): 214, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38528619

RESUMO

BACKGROUND: Endovascular repair of aortic aneurysmal disease is established due to perceived advantages in patient survival, reduced postoperative complications, and shorter hospital lengths of stay. High spatial and contrast resolution 3D CT angiography images are used to plan the procedures and inform device selection and manufacture, but in standard care, the surgery is performed using image-guidance from 2D X-ray fluoroscopy with injection of nephrotoxic contrast material to visualise the blood vessels. This study aims to assess the benefit to patients, practitioners, and the health service of a novel image fusion medical device (Cydar EV), which allows this high-resolution 3D information to be available to operators at the time of surgery. METHODS: The trial is a multi-centre, open label, two-armed randomised controlled clinical trial of 340 patient, randomised 1:1 to either standard treatment in endovascular aneurysm repair or treatment using Cydar EV, a CE-marked medical device comprising of cloud computing, augmented intelligence, and computer vision. The primary outcome is procedural time, with secondary outcomes of procedural efficiency, technical effectiveness, patient outcomes, and cost-effectiveness. Patients with a clinical diagnosis of AAA or TAAA suitable for endovascular repair and able to provide written informed consent will be invited to participate. DISCUSSION: This trial is the first randomised controlled trial evaluating advanced image fusion technology in endovascular aortic surgery and is well placed to evaluate the effect of this technology on patient outcomes and cost to the NHS. TRIAL REGISTRATION: ISRCTN13832085. Dec. 3, 2021.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Análise Custo-Benefício , Computação em Nuvem , Procedimentos Endovasculares/métodos , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
15.
Kyobu Geka ; 77(3): 213-216, 2024 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-38465494

RESUMO

Formation of a pseudoaneurysm due to blood leakage from the anastomotic site of the vascular graft in large-diameter vessels is often seen, but formation of a pseudoaneurysm from the non-anastomotic site is extremely rare. A 68-year-old woman presented with a history of double valve replacement for combined valvular disease at 37 years old and hemiarch replacement for thoracic aortic dilatation at 65 years old. She visited the emergency room with a 2-week history of chest pain. Contrast-enhanced computed tomography (CT) revealed a 5-cm-diameter pseudoaneurysm and extravasation from the ascending aorta, so emergency surgery was performed. Around the ascending aorta area, we confirmed bleeding from a 5-mm dehiscence in the non-anastomotic part of the graft prosthesis, so hemostasis was performed with a cross-stitch mattress suture over a felt strip. Initially, the cause of the pseudoaneurysm was unknown, but re-examination of CT images from after the previous hemiarch replacement confirmed contact between the sternal wire and graft prosthesis. The wire was thus considered to have caused damage and bleeding. The patient was discharged from the hospital with a good postoperative course and is being followed-up in the outpatient department.


Assuntos
Falso Aneurisma , Implante de Prótese Vascular , Idoso , Feminino , Humanos , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Aorta/cirurgia , Substitutos Sanguíneos , Implante de Prótese Vascular/efeitos adversos
16.
BMC Cardiovasc Disord ; 24(1): 182, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38532333

RESUMO

OBJECTIVE: To evaluate the early and mid-term outcomes of open repair in patients with thoracoabdominal aortic aneurysm (TAAA) after thoracic endovascular aortic repair (TEVAR). METHODS: This was a retrospective single center study. Data were retrospectively collected and analyzed for consecutive patients undergoing open TAAA repair (TAAAR) after TEVAR from November 2016 to June 2021. Indications for TAAAR included aneurysm progression due to endoleak, persisted false lumen perfusion, proximal/distal disease progression, and aorta rupture. The risk factor of operative mortality was analyzed by multivariable logistic regression model and the survival was evaluated by Kaplan-Meier. RESULTS: Sixty-three patients who met the inclusion criteria for the study were identified. The mean age at TAAAR was 41 ± 12 years and 43 (68.3%) were male. Marfan syndrome (MFS) was presented in 39 patients (61.9%). 60 (95.2%) patients presented with post-dissection aneurysm and 3 (4.8%) patients with degenerative aneurysm. The extent of TAAA was Crawford I in 9 (14.3%), II in 22 (34.9%), III in 23 (36.5%), and IV in 9 (14.3%). Emergent TAAAR was done in 10 (15.9%) patients, and deep hypothermic circulatory arrest was used in 22 (34.6%). Endograft was explanted in 31 (49.2%). Operative mortality was 11 (17.5%). Stroke, paraplegia, and acute kidney failure occurred in 5 (7.9%), 7 (11.1%), and 6 (9.5%) patients, respectively. Pulmonary complications occurred in 19 (30.2%) patients. The estimated survival was 74.8 ± 4.9% at 5 years. Late reoperations were performed in 2 patients at 2.5 years and 1.3 years, respectively. CONCLUSIONS: In this series of TAAA after TEVAR, TAAAR was related with a high risk of operative mortality and morbidity and the midterm outcomes represented a durable treatment and were respectable.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Feminino , Correção Endovascular de Aneurisma , Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Aneurisma da Aorta Torácica/cirurgia , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Complicações Pós-Operatórias
17.
Turk Kardiyol Dern Ars ; 52(2): 88-95, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38465530

RESUMO

OBJECTIVE: Aortic rupture is a rare and catastrophic emergency. Prompt diagnosis and treatment are the primary determinants of mortality. During follow-up, the majority of patients who have been effectively treated die from hypovolemic shock and multiorgan failure. This article describes the clinical and procedural details of sixteen patients with ruptured aortic aneurysms treated endovascularly. In addition, it discusses the main factors contributing to the mortality of these patients. METHOD: Patients who underwent endovascular treatment for acute aortic rupture at our center from October 2016 to March 2023 were included in this retrospective study. RESULTS: A total of 16 patients underwent endovascular aneurysm repair (EVAR) or thoracic endovascular aneurysm repair (TEVAR) for acute aortic rupture. The patients' mean age was 73.06 years (range: 52-92), and 15 of them were male. The ruptures occurred in the abdominal aortic aneurysm in ten patients, in thoracic aortic aneurysm in three patients, in the isolated iliac artery aneurysm in two patients, and there was one case of non-aneurysmal aortic rupture. In our series, patients who presented with an impending, self-limited rupture and stable hemodynamic status had good prognostic outcomes. However, eight patients died due to multiorgan failure, hemorrhagic shock, disseminated intravascular coagulopathy, renal failure, or abdominal compartment syndrome. These patients generally had poor admission vital signs and low hemoglobin values. The most critical determinants for the success of the procedure are promptly stopping the bleeding, avoiding general anesthesia, and opting for blood product replacement instead of fluid replacement. CONCLUSION: Each patient with ruptured aortic aneurysm should be managed according to the patient's hemodynamics at presentation, the size of the aneurysm, the suitability for percutaneous procedure, logistical factors, and the operator-center's experience.


Assuntos
Aneurisma da Aorta Abdominal , Ruptura Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Feminino , Humanos , Masculino , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/métodos , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais
18.
J Cardiothorac Surg ; 19(1): 121, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38481295

RESUMO

BACKGROUND: This study aims to identify the risk factors contributing to spinal cord injury (SCI) following a type A acute aortic dissection (TA-AAD). METHODS: This retrospective study was conducted at a single center and involved 481 patients who received frozen elephant trunk stent implantation for TA-AAD. Additionally, these patients underwent total arch replacement with deep hypothermic circulatory arrest. This study was performed at Fuwai Hospital between September 2016 and April 2020. RESULTS: The resulting data of the multivariate logistic regression analysis demonstrated that preoperative platelet count (odds ratio [OR] = 0.774) and D-dimer levels (OR = 2.247) could serve as independent predictors for postoperative SCI in patients with TA-AAD. CONCLUSION: The findings indicate that preoperative platelet count and D-dimer levels are independent risk factors for postoperative SCI in patients with TA-AAD. This study holds significant clinical implications regarding the prognosis and therapeutic responses for patients with TA-AAD.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Produtos de Degradação da Fibrina e do Fibrinogênio , Traumatismos da Medula Espinal , Humanos , Estudos Retrospectivos , Contagem de Plaquetas , Implante de Prótese Vascular/métodos , Dissecção Aórtica/cirurgia , Traumatismos da Medula Espinal/etiologia , Fatores de Risco , Aneurisma da Aorta Torácica/complicações , Aorta Torácica/cirurgia , Resultado do Tratamento
19.
Medicina (Kaunas) ; 60(3)2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38541169

RESUMO

Background and Objectives: Acute type A aortic dissection (AAD) is a life-threatening disease. No differences between men and women have been made in the treatment of AAD so far and knowledge about sex differences regarding long-term outcomes is limited. Materials and Methods: Between 01/2004 and 12/2021, 874 patients were operated on for AAD, including 313 (35.8%) women and 561 (64.2%) men. Clinical and surgical records, including long-term follow-up information, were obtained and analyzed retrospectively. To account for differences in the outcome determined by different preoperative life expectancies, a subgroup analysis for a set of patients matched according to their remaining life expectancy was performed. Results: At the time of AAD, women were older than men (69.1 ± 13.0 vs. 61.8 ± 13.3 years, p < 0.001) and had a shorter remaining statistical life expectancy (18.6 ± 10.8 vs. 21.4 ± 10.4 years, p < 0.001). Significantly more DeBakey type II AAD was found in women (37.1% vs. 25.7%, p < 0.001). Comorbidities and preoperative status at the time of presentation were similar in women and men. More hemiarch procedures (63.3% vs. 52.0%, p < 0.001) and less arch replacements (8.6% vs. 16.6%, p < 0.001) were performed in women, resulting in shorter cross-clamp times for women (92 ± 39 vs. 102 ± 49 min, p < 0.001). The in-hospital mortality was similar in women and men (11.5% vs. 12.7%, p = 0.618). Long-term survival was significantly shorter in women compared to men (9.8 [8.1-11.5] vs. 15.1 [11.9-18.4] years, p = 0.011). A matched subgroup analysis revealed that when comparing groups with a similar remaining life expectancy, the long-term survival showed no significant differences between women and men (9.8 [7.9-11.6] vs. 12.4 [10.1-14.7] years, p = 0.487). Conclusions: There are sex differences in AAD, with DeBakey type II dissection being more frequent in women. The seemingly worse long-term outcome can mostly be attributed to the shorter remaining statistical life expectancy at the time of presentation.


Assuntos
Dissecção Aórtica , Implante de Prótese Vascular , Humanos , Masculino , Feminino , Estudos Retrospectivos , Caracteres Sexuais , Resultado do Tratamento , Dissecção Aórtica/cirurgia , Fatores de Risco , Doença Aguda
20.
BMJ Case Rep ; 17(3)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38521516

RESUMO

A patient in his late 30s presented with issues of retrosternal chest pain and palpitations. He had sustained a splinter injury to the left hemithorax a year ago for which he had been managed with a tube thoracostomy. During subsequent evaluations, he was found to have atrial fibrillations and a CT angiography revealed an arch of the aorta pseudoaneurysm with a fistulous communication with the innominate vein, which being a rare condition has no established treatment protocols. Endovascular salvage of the condition required an aortic Ishimaru zone 2 deployment of the thoracic endovascular aortic repair stent graft to provide an adequate landing zone. The elective left subclavian artery revascularisation was obtained by a left carotid artery to left subclavian artery bypass. Post procedure there was complete exclusion of the pseudoaneurysm sac, and the fistulous aorto-venous communication inflow tract. The patient recuperated well and has returned to full active duties.


Assuntos
Falso Aneurisma , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Traumatismos Torácicos , Humanos , Masculino , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aorta Torácica/lesões , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Veias Braquiocefálicas/diagnóstico por imagem , Veias Braquiocefálicas/cirurgia , Desenho de Prótese , Stents , Traumatismos Torácicos/cirurgia , Resultado do Tratamento , Adulto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...